Operations And Procedures Manual for Trans-Data On Board Weight Systems

Trans-Data Ticket Set Up Examples

 

TICKET SET UP 3.7.2 (Rev. 1.44)
Example of a Static Weight System on All Axle Sensor Mounted Vehicles
Designed for Commodity Haulers, Roll-off Trucks, and other single load applications

 
Stop Seq.(Stop # 1)(Stop # 2)(Stop # 3)
ACCT.#ID: 0223ID: 0224ID: 0225
NameAny Name HaulingAny Name HaulingAny Name Hauling
Time/Date08:23:46 29/06/200508:35:51 29/06/200508:41:32 29/06/2005
In WeightGross 49,500 lbs.Gross 41,250 lbs.Gross 38,750 lbs.
Out WeightTare 41,250 lbs.Tare 38,750 lbs.Tare 34,300 lbs.
Net LoadNet 8,250 lbs.Net 2,500 lbs.Net 4,450 lbs.

 

TICKET SET UP 3.7.3 (Rev. 1.38 & above)
Example of a Static Weight System on Front Bin ONLY Commercial Vehicles
Designed for Auditing Selected Customer Accounts on a Front Loader

 
Stop Seq.(Stop # 1)(Stop # 2)(Stop # 3)
ACCT.#ID: 0223ID: 0224ID: 0225
NameAny Name HaulingAny Name HaulingAny Name Hauling
Time/Date08:23:46 29/06/200508:35:51 29/06/200508:41:32 29/06/2005
In WeightGross 1400 lbs.Gross 4680 lbs.Gross 3560 lbs.
Bin Weight00 lb Tare 580 lb00 lb Tare 650 lb00 lb Tare 450 lb
Net LoadNet 820 lbNet 4030 lbNet 3110 lb

 

TICKET SET UP 3.7.4 (Rev. 1.42)
Example of a Static Weight System on a Rear Loader
Designed for Auditing Selected Customer Accounts on a Rear Loader

 
Stop Seq.(Stop # 1)(Stop # 2)(Stop # 3)
ACCT.#ID: 0223ID: 0224ID: 0225
NameAny Name HaulingAny Name HaulingAny Name Hauling
Time/Date08:23:46 29/06/200508:35:51 29/06/200508:41:32 29/06/2005
In WeightGross 1400 lbs.Gross 4680 lbs.Gross 3560 lbs.
Bin Weight00 lb Tare 1100 lb00 lb Tare 1100 lb00 lb Tare 1100 lb
Net LoadNet 300 lbNet 3580 lbNet 2480 lb

 

Above is an example derived from a ticket set up which can be sent to a printer or modem.

To access the ticket mode, the meter must first be in the calibration mode. For a new ticket in sequence, enter Parameter [84], then press [SELECT].

To edit an existing ticket, enter Parameter [85], then press [SELECT]. The meter will display “edit”. Enter the ticket number you wish to edit and press T.

Once in the ticket mode, to enter the letter “C” before a numerical number, press [OUT] once. To enter the letter “P” before a numerical number, press [OUT] twice as shown below.

After each numerical entry is made, press [SELECT]. Example: 32,32,32,32 [C20] = 32 [SELECT] 32 [SELECT] 32 [SELECT] 32 [SELECT] then press [OUT] then [20][SELECT].

To navigate within a single ticket

To scroll forward in a single ticket, press the blue [–0–] to scroll to the next entry. To scroll backward in a single ticket, press the blue [on/off] to scroll to the previous entry as shown below.

Trans-Data Digital Meter